Flanged Flow Nozzles
Flanged flow nozzles are constructed with a mounting flange in line
with the contoured upstream face. The mounting flange is sandwiched
between the end-user’s pipe flanges to hold and seal the flow
nozzle inside of the process piping. The mounting flange can be
provided with a raised gasket face or RTJ groove, as required. Every
flanged flow nozzle has a precision-machined shoulder to help assure
its concentricity with the adjacent pipe.
The Wyatt Engineering Flanged Flow Nozzle is
installed between pipe flanges when the customer/end-user is providing
the taps for the upstream and downstream pressure sensation. The
flow contour is machined to ASME
or ISO specifications and a shoulder is provided on the downstream
side of the mounting flange to center the nozzle within required
tolerances.

Note that the high pressure tap is nominally placed one pipe inside
diameter (D) upstream from the nozzle face and the low pressure
tap is located one-half a pipe diameter (D/2) downstream from the
nozzle face. Given this tapping
configuration, several combinations of line size and flange geometry
may preclude proper tap placement or violate certain piping and
pressure vessel codes. Inform your Wyatt Engineering representative
if this is the case, and we will provide special designs to solve
the problem.

The Wyatt Flanged Flow Nozzle with Integral Low Pressure
Tap is provided with the downstream tap integral to the
nozzle’s mounting flange. This design
provides the same ASME or ISO flow contour, but can be used in smaller
pipe sizes where the low pressure tap may interfere with the pipe
weld, flange, and/or flange bolting. The low pressure connection
is typically 1/4" NPT (6 mm)
unless specified otherwise.
Weld-In Flow Nozzles
Wyatt Engineering’s Weld-In Flow Nozzle is
used where pipe flanges are not or cannot be used, such as in high
pressure and/or high temperature applications in power plant installations.
This flow nozzle design has a small mounting

flange designed to fit between beveled ends of the inlet and outlet
pipe section. The pipe sections are then welded together with the
nozzle in place.

The weld-in flow nozzle design can be provided as a special Mounting
Ring Flow Nozzle that eliminates the need for welding dissimilar
metals in the field. Note that pipe wall pressure taps are used
with this nozzle design and
that it is available in complete flow metering section.

For special applications and in smaller line sizes, Wyatt Engineering
provides a Weld-In Flow Nozzle with Integral Metering Taps.
This design may include a short section of upstream and
downstream pipe with flanged, beveled, or socket-weld ends.
Return to top of page
|